    摘要:

    10 kV线路一般以树枝辐射状供电,支线末梢容易出现低电压问题,分析10 kV线路安全供电的典型区域面积是研究配网扩张及规划方法的基础。分析10 kV线路的沿线压降特性,获取全线压降的简化计算方法;通过对10 kV配网供电区域的分解,得到以主线为中轴、支线承载的负荷均衡分布的矩形、菱形及前、后三角形等4类10 kV线路典型供电区域模型;对典型供电区域进行边界压降分析,得到线路总负荷、线型与区域边界压降的关系,进而得到边界电压安全约束下的各类典型供电区域的最大面积。10 kV线路典型供电区域及安全供电面积分析,可为新区配网的变电站布点、网架布局及线型选择提供理论依据,具有理论意义及工程价值。

    Abstract:

    Power supply via 10 kV lines is generally achieved in a radial branch structure, and low voltage problems are prone to occur at the end of the branch lines. The analysis of typical areas with safe power supply via 10 kV lines is the basis for the study of distribution network expansion and planning methods. The voltage drop characteristics of 10 kV lines are analyzed, and a simplified calculation method for the voltage drop along the line is derived. The power supply areas of the 10 kV distribution network are decomposed into four typical supply area models: rectangular, diamond-shaped, front-triangular, and rear-triangular. Each model uses the main lines as the central axis, with the branch lines bearing balanced loads. The boundary voltage drop of each typical area is analyzed, and the relationship among the total load, line type, and boundary voltage drop is established, thereby determining the maximum area of each type of typical power supply area under boundary voltage safety constraints. The analysis of typical power supply areas and their corresponding safe power supply capacities via 10 kV lines provides a theoretical basis for substation siting, grid layout, and line type selection in newly developed distribution areas, with both theoretical significance and engineering value.

    参考文献
    相似文献
    引证文献
引用本文

竺 炜,洪汝舟,李爱元,等.10 kV线路安全供电的典型区域模型分析[J].电力科学与技术学报,2025,40(3):96-103.
ZHU Wei, HONG Ruzhou, LI Aiyuan, et al. Model analysis of typical areas with safe power supply via 10 kV lines[J]. Journal of Electric Power Science and Technology,2025,40(3):96-103.