新型电力系统输电线路故障暂态波形的多维时频特性表征
CSTR:
作者:
作者单位:

(1.南方电网云南电网有限责任公司电力科学研究院 ,云南 昆明 650011;2.武汉理工大学自动化学院 ,湖北 武汉 430070)

作者简介:

通讯作者:

唐金锐(1986—),男,博士,副教授,主要从事电力系统继电保护技术等方面的研究;E-mail:tangjinrui@whut.edu.cn

中图分类号:

TM773

基金项目:

云南电网公司科技项目计划(YNKJXM20222034)


Multi -dimensional time -frequen cy charac terization of transient waveforms on transmission line faults in ne w electric power systems
Author:
Affiliation:

(1. Electric Power Research Institute , Yunnan Electric Power Grid Co ., Ltd., China Southern Power Grid , Kunming 650011, China;2. School of Automation , Wuhan Un ivers ity of Technology , Wuhan 430070, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    大规模新能源、储能及大容量柔性交直流 输电设备广泛接入新型电力系统后,输电线路故障电流和电压波形稳态工频相、序分量将主要取决于电力电子设备低电压穿越策略、紧急控制策略与电子元器件限流环节,传统的基于工频量继电保护算法的性能显著下降。基于非工频暂态分量的新型继电保护算法可充分利用输电线路故障本身引起的暂态充放电过程,识别出区内、外故障。借鉴刻画波形特征的信息论方法,提出基于暂态分量时域波形和频谱分布的幅值及变化率等多维时频特性表征方法,充分挖掘输电线路区内外故障时暂态波形特征差异。研究结果表明,部分时频特性指标在特定时间窗和频率带内受电力电子设备影响小,发生区内、外故障时其差异明显。该表征方法可用于研究和测试新型继电保护算法,为新型电力系统安全与可靠运行提供有力支撑。

    Abstract:

    When large-scale new energy,energy sto rage,and large-capacity flexible alternative current (AC) and direct current (DC) transmission equipment are integrated into new electric power systems,steady-state power frequency phase,and sequence component of current and voltage waveforms in transmission line faults are mainly depend on the low voltage ride through strategy of power electronic equipment,emergency control strategy,and current limiting link of electronic components and devices.The performance of traditional relay protection algorithms is significantly based on the power frequency.A new relay protection algorithm based on non-power-frequency transient components can make full use of the transient charging and discharging process caused by transmission line faults to distinguish between internal and external faults.Inspired by information-theoretic methods for characterizing waveform features,a multi-dimensional time-frequency characterization approach is proposed,which is based on the amplitude and variation rate of transient components in both the time-domain waveform and spectral distribution.This method fully exploits the differences in transient waveform features between internal and external faults on transmission lines.The research results show that some time-frequency characterization indexes are less affected by the power electronic equipment in the given time window and frequency band,while exhibiting significant differences between internal and external faults.The proposed characterization method can be applied to the study and testing of new relay protection algorithms,providing strong support for the safe and reliable operation of new electric power systems.

    参考文献
    相似文献
    引证文献
引用本文

张丽,李胜男,王是尧,等.新型电力系统输电线路故障暂态波形的多维时频特性表征[J].电力科学与技术学报,2025,(4):24-37.