基于功率矩的配电网柔性互联系统选址及互联功率优化
CSTR:
作者:
作者单位:

(1.云南电网有限责任公司电力科学研究院 ,云南 昆明 650000;2.湖南大学电气与信息工程学院 ,湖南 长沙 410000)

作者简介:

通讯作者:

杨金东(1984—),男,博士,高级工程师,主要从事配电网无功电压控制、中低压柔性互联运行控制、配电网绝缘状态监测及故障查找定位等方面的研究;E-mial:1440771598@qq.com

中图分类号:

TM715

基金项目:

南方电网云南电网科技项目(0562002023030301PD00004)


Flexible interconnected system location of distribution networks and interconnection power optimization based on power moment
Author:
Affiliation:

(1. Electric Power Research Institute , Yunnan Power Grid Co ., Ltd., Kunming 650000, China; 2. College of Electrical and Information Engineering , Hunan University , Changsha 410000, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    配电网柔性互联可实现变压器的动态增容,是提高新型配电网电能质量的有效途径。提出一种基于功率矩最小的互联点选择方法,综合考虑配电网源荷状态及其互补关系,得到对应状态下的最佳互联点。先以全年不同时间段的互联线路负载率之差为权重,获取准全寿命周期的最佳互联点位置;再基于所提出的互联节点,提出一种新的基于互联系统损耗最小的互联点注入电流计算方法;然后,考虑线路损耗、变压器损耗和变流器损耗,以互联系统总损耗最小为目标函数,在满足互联功率平衡和配电网容量约束的情况下,得到互联点注入电流值,进而得到互联功率;最后,将其用于实例。研究结果表明,所提方法在 2个实际配电网互联中的总损耗均小于传统的首端互联方法的总损耗。

    Abstract:

    Flexible interconnection of distribution networks can achieve dynamic capacity expansion of transformers,which is an effective way to improve the power quality of new distribution networks.This paper proposes a method for selecting interconnection points based on the minimum power moment,which comprehensively considers the source load state and its complementary relationship in the distribution network,obtaining the optimal interconnection point in the corresponding state.The location of the optimal interconnection point for the quasi full life cycle is obtained by employing the difference in load rates of interconnection lines during different periods throughout the year as the weight coefficient.Based on the proposed interconnection node,a method for calculating the injection current at the interconnection point with minimum system loss is proposed.Then,by considering line loss,transformer loss,and inverter loss,and taking the minimal total loss of the interconnected system as the objective function,the injection current at the interconnection point is obtained in the condition of satisfying the constraints of interconnection power balance and distribution network capacity,thus obtaining the interconnection power.Finally,the results are applied to practical cases.The study shows that the proposed method achieves a smaller total loss in the interconnection of two actual distribution networks than traditional head end interconnection methods.

    参考文献
    相似文献
    引证文献
引用本文

杨金东,张锡然,任超行,等.基于功率矩的配电网柔性互联系统选址及互联功率优化[J].电力科学与技术学报,2025,(4):50-60.
YANG Jindong, ZHANG Xiran, REN Chaohang, et al. Flexible interconnected system location of distribution networks and interconnection power optimization based on power moment[J]. Journal of Electric Power Science and Technology,2025,(4):50-60.

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2024-03-13
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2025-10-27
  • 出版日期:
文章二维码