Research on control method of flexible grounding device for suppressing threephase unbalance in distribution network
CSTR:
Author:
Clc Number:

TM77

  • Article
  • | |
  • Metrics
  • |
  • Reference [20]
  • | | | |
  • Comments
    Abstract:

    In order to improve the stability and signal tracking ability of existing flexible grounding devices to suppress the threephase unbalance in distribution networks, a flexible grounding control method is proposed based on the improved double closedloop control strategy. Firstly, the control system is modeled and analyzed, and an injection current control strategy is proposed. This strategy is based on the double closedloop control and it adopts the current innerloop PI control and voltage outerloop hysteresis network control. By setting the reference value of neutral point voltage to zero and taking it as the control target, the difference between the reference value and the feedback value of neutral point voltage is compared in real time. And then the difference goes through the series lag correction. Thus, it can be treated as a reference current in the current inner loop. The deviation between the theoretical reference current and the actual measurement current is taken as the input of PI correction link. For the outer loop output, the target control for the output current is realized, the stability margin of current is effectively improved and the tracking time of output and input signals is shorten. The good performance of proposed method in threephase unbalanced overvoltage suppression is verified by a system simulation analysis. Neutral point voltage in distribution network is accurately suppressed to zero.

    Reference
    [1] 刘锋.电网不平衡下三相锁相环研究[D].成都:电子科技大学,2013.
    [2] Kalyuzhny A.Analysis of temporary overvoltages during openphase faults in distribution networks with resonant grounding[J].IEEE Transactions on Power Delivery,2015,30(1):420427.
    [3] 胡京莹.基于零序电压柔性控制的配电网过电压抑制技术研究[D].长沙:长沙理工大学,2013.
    [4] Liu M,Zhao J X.The compensation effect of the distributed Arc suppression coil in 10kV network system[C]//IECON 2016 42nd Annual Conference of the IEEE Industrial Electronics Society,Florence,Italy:IEEE,2016.
    [5] 李家靖,严欣,袁佳欣,等.三相不平衡条件下低压配电网合环操作研究[J].电力科学与技术学报,2018,33(2):117122.LI Jiajing,YAN Xin,YUAN Jiaxin,et al.Study on closed loop operation of low voltage distribution network under threephase unbalanced condition[J].Journal of Electric Power Science and Technology,2018,33(2):117122.
    [6] 余文辉,李健,陈祖勋.配电网接地故障电压消弧新方法[J].电力科学与技术学报,2012,27(1):6469.YU Wenhui,LI Jian,CHEN Zuxun.A novel voltage arcsuppression method for grounding faults in distribution networks[J].Journal of Electric Power Science and Technology,2012,27(1):6469.
    [7] 陈锐,周丰,翁洪杰,等.基于双闭环控制的柔性接地装置消弧方法[J].电力科学与技术学报,2015,30(4):6370.CHEN Rui,ZHOU Feng,WENG Hongjie,et al.Flexible grounding device with the dualloop control method for arc suppression[J].Journal of Electric Power Science and Technology,2015,30(4):6370.
    [8] 颜湘武,王月茹,王星海,等.逆变器并联功率解耦及鲁棒下垂控制方法研究[J].电力科学与技术学报,2016,31(1):1116.YAN Xiangwu,WANG Yueru,WANG Xinghai,et al.Study on power decoupling and robust droop control method of parallel inverter[J].Journal of Electric Power Science and Technology,2016,31(1):1116.
    [9] 薛尚青,蔡金锭.风电场不同控制策略对电网电压稳定影响的分析[J].电力科学与技术学报,2011,26(3):5762.XUE Shangqing,CAI Jinding.Impacts of wind farms with different control strategies on power grids voltage stability[J].Journal of Electric Power Science and Technology,2011,26(3):5762.
    [10] 曾祥君,胡京莹,王媛媛,等.基于柔性接地技术的配电网三相不平衡过电压抑制方法[J].中国电机工程学报,2014,34(4):678684.ZENG Xiangjun,HU Jingying,WANG Yuanyuan,et al.Suppressing method of threephase unbalanced overvoltage based on distribution networks flexible grounding control[J].Proceedings of the CSEE,2014,34(4):678684.
    [11] 彭沙沙,曾祥君,喻琨,等.基于二次注入的配电网接地故障有源电压消弧方法[J].电力系统保护与控制,2018,46(20):142149.PENG Shasha,ZENG Xiangjun,YU Kun,et al.Active arcsuppression method of grounding fault for distribution network based on secondary injection [J].Power System Protection and Control,2018,46(20):142149.
    [12] 曾祥君,黄明玮,王文,等.配电网三相不平衡过电压有源抑制方法研究[J].电工技术学报,2015,30(9):6169.ZENG Xiangjun,HUANG Mingwei,WANG Wen,et al.Research on active suppression method of threephase unbalanced overvoltage for distribution networks[J].Transactions of China Electrotechnical Society,2015,30(9):6169.
    [13] 齐郑,李鸿毅.孤岛模式下的微网多PT铁磁谐振的研究[J].电力系统保护与控制,2019,47(22):5258.QI Zheng,LI Hongyi.Research on multiPT ferroresonance in island microgrid [J].Power System Protection and Control,2019,47(22):5258.
    [14] 兰佳,汪东,陈娅,等.双级式光伏发电并网系统控制策略及仿真研究[J].电力科学与技术学报,2019,34(4):129136.LAN Jia,WANG dong,CHEN Ya,et al.Research on control strategy and simulation of double stage photovoltaic grid connected system [J].Journal of Electric Power Science and Technology,2019,34(4):129136.
    [15] Dan A M,Czira Z,Raisz D.Decreasing the harmonic content of the fault current during singlephase to ground faults in compensated network [C]//2009 IEEE Bucharest PowerTech,Bucharest,Romania:IEEE,2009.
    [16] 胡寿松.自动控制原理[M].北京:科学出版社,2007.
    [17] 张红洁,董祖晨,何晓明,等.适用于不同类型滤波器的光伏逆变器控制策略研究[J].智慧电力,2018,46(2):2027+82.ZHANG Hongjie,DONG Zuchen,HE Xiaoming,et al.Study of control strategy for PV inverter considering Impact of Filters[J].Automation of Electric Power Systerms,2018,46(2):2027+82.
    [18] 鲍陈磊,阮新波,王学华,等.基于PI调节器和电容电流反馈有源阻尼的LCL型并网逆变器闭环参数设计[J].中国电机工程学报,2012,32(25):133142+19.BAO Chenlei,RUAN Xinbo,WANG Xuehua,et al.Design of gridconnected inverters with LCL filter based on PI regulator and capacitor current feedback active damping[J].Proceedings of the CSEE,2012,32(25):133142+19.
    [19] Li Z P,Jiang A T,Shen P,et al.Resonance damping and parameter design method for LCLLC filter interfaced gridconnected photovoltaic inverters[C]//2016 IEEE 8th International Power Electronics and Motion Control Conference(IPEMCECCE Asia),Hefei,China:IEEE,2016.
    [20] 张明奇,张英敏,田洪江,等.一种MMC控制系统的复合校正策略[J].智慧电力,2019,47(8):6975.ZHANG Qiming,ZHANG Yingming,TIAN Hongjiang,et al.A compound correction strategy for MMC control system [J].Smart Power,2019,47(8):6975.
    Related
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

曾祥君,李 理,喻 锟,陈朵红,李建华,车晓涛.抑制配电网三相不平衡的柔性接地装置控制方法[J].电力科学与技术学报英文版,2020,35(3):19-28. ZENG Xiangjun, LI Li, YU Kun, CHEN Duohong, LI Jianhua, CHE Xiaotao. Research on control method of flexible grounding device for suppressing threephase unbalance in distribution network[J]. Journal of Electric Power Science and Technology,2020,35(3):19-28.

Copy
Share
Article Metrics
  • Abstract:313
  • PDF: 0
  • HTML: 0
  • Cited by: 0
History
  • Online: September 14,2020
Article QR Code