Fault location method for highvoltage cable shortcircuit based on electromagnetic time reversal
CSTR:
Author:
Clc Number:

TM755

  • Article
  • | |
  • Metrics
  • |
  • Reference [23]
  • | | | |
  • Comments
    Abstract:

    In order to effectively locate shortcircuit faults in the highvoltage singlecore cable, this paper presents a new method based on the electromagnetic timereversal (EMTR) theory. As the fault location is the maximum energy point, this method monitors the sheath current at the grounding position of the highvoltage terminal and calculates the energy of each guessing fault location by the transfer function of the fault signal. A typical highvoltage cable structure is simulated and analyzed. The results show that the method can effectively locate the fault point, and the accuracy can be improved with the increase of the sampling rate. It is recommended of the above 10 MHz sampling rate in practical applications.

    Reference
    [1] 刘金凯,梁永亮,郭宏,等.脐带缆电缆故障电压行波相模分量特征分析及测距方法研究[J].供用电,2021,38(2):19-25.LIU Jinkai,LIANG Yongliang,GUO Hong,et al.Characteristic analysis of traveling wave phase mode component of umbilical cable fault voltage and research on fault location method[J].Distribution & Utilization,2021,38(2):19-25.
    [2] LI Mingzhen,ZHOU Wenjun,WANG Chunlin,et al.A novel fault localization method based on monitoring of sheath current in a crossbonded HV cable system[C]//IEEE Electrical Insulation Conference,Baltimore,MD,USA,2017.
    [3] 周承科,李明贞,王航,等.电力电缆资产的状态评估与运维决策综述[J].高电压技术,2016,42(8):2353-2362.ZHOU Chengke,LI Mingzhen,WANG Hang,et al.Review of condition assessment and maintenance strategy of power cable assets[J].High Voltage Engineering,2016,42(8):2353-2362.
    [4] 蒋原,李擎,冯茜,等.基于BP神经网络的直流电网故障定位与保护方法[J].高压电器,2020,56(8):23-28.JIANG Yuan,LI Qing,FENG Qian,et al.Fault location and protection method for DC power grid based on BP neural network[J].High Voltage Apparatus,2020,56(8):23-28.
    [5] 李福志,郑卫宾,张文海,等.基于回路直流电阻测量的输电线路单相接地故障离线故障定位[J].中国电力,2021,54(2):140-146.LI Fuzhi,ZHENG Weibin,ZHANG Wenhai,et al.Fault path directcurrent resistance based offline singlephasetoground fault location[J].Electric Power,2021,54(2):140-146.
    [6] 赵尊慧,郑柒拾,孙廷玺,等.基于光纤脉冲传输的海缆故障测距系统及方法[J].电测与仪表,2020,57(10):24-29.ZHAO Zunhui,ZHENG Qishi,SUN Tingxi,et al.Submarine cable fault location system and method based on optical fiber pulse transmission[J].Electrical Measurement & Instrumentation,2020,57(10):24-29.
    [7] Eissa M.Ground distance relay compensation based on fault resistance calculation[J].IEEE Transactions on Power Delivery,2006,29(4):1830-1835.
    [8] 刘洋,曹云东,侯春光.基于经验模态分解及维格纳威尔分布的电缆双端故障定位算法[J].中国电机工程学报,2015,35(16):4086-4093.LIU Yang,CAO Yundong,HOU Chunguang.The cable twoterminal fault location algorithm based on EMD and WVD[J].Proceedings of the CSEE,2015,35(16):4086-4093.
    [9] 张安安,周志通,庄景泰,等.基于行波瞬时振幅的高压直流输电线路故障测距方法研究[J].智慧电力,2020,48(2):78-84.ZHANG Anan,ZHOU Zhitong,ZHUANG Jingtai,et al.Fault location method of HVDC transmission line based on traveling wave instantaneous amplitude[J].Smart Power,2020,48(2):78-84.
    [10] 孙广,王阳,薛枫,等.特高压直流输电线路改进双端行波故障定位方法研究[J].电力系统保护与控制,2020,48(14):113-120.SUN Guang,WANG Yang,XUE Feng,et al.Research on an improved doubleterminal traveling wave fault location method for UHVDC project[J].Power System Protection and Control,2020,48(14):113-120.
    [11] 张怿宁,孟令军,王越杨,等.基于非接触式行波采集的分布式高压直流故障测距方法[J].电网与清洁能源,2020,36(4):55-59.ZHANG Yining,MENG Lingjun,WANG Yueyang,et al.A fault location method for distributed HVDC high resistance fault based on noncontact traveling wave collecting[J].Power System and Clean Energy,2020,36(4):55-59.
    [12] De Aguiar R A,Dalcastagnê A L,Zürn H H,et al.Impedancebased fault location methods:Sensitivity analysis and performance improvement[J].Electric Power Systems Research,2018,155:236-245.
    [13] Dashti R,Daisy M,Shaker H R,et al.Impedancebased fault location method for fourwire power distribution networks[J].IEEE Access 2018,6:1342-1349.
    [14] Gabr M A,Ibrahim D K,Ahmed E S,et al.A new impedancebased fault location scheme for overhead unbalanced radial distribution networks[J].Electrical Power Systems Research,2017,142:153-162.
    [15] 曾祥君,邓丰,李泽文,等.基本信息融合的故障行波定位网络算法[J].电力科学与技术学报,2009,24(1):38-43.ZENG Xiangjun,DENG Feng,LI Zewen.Fault traveling wave location network algorithms based on basic information fusion[J].Journal of Electric Power Science and Technology,2009,24(1):38-43.
    [16] 张健,王奕,曾祥君,等.基于多端行波到达时差的配电网故障选线方法[J].电力科学与技术学报,2016,31(4):51-57.ZHANG Jian,WANG Yi,ZENG Xiangjun.Distribution network fault line selection method based on multiterminal traveling wave arrival time difference[J].Journal of Electric Power Science and Technology,2016,31(4):51-57.
    [17] Chen R,Lin T,Bi R,et al.Novel strategy for accurate locating of voltage sag sources in smart distribution networks with inverterinterfaced distributed generators[J].Energies,2017,10:18-85.
    [18] Fink M.Time reversal of ultrasonic fields.I.Basic principles[J].IEEE Transactions on Ultrasonics Ferroelectrics & Frequency Control,1992,39(5):555-566.
    [19] Daisy M,Dashti R.Single phase fault location in electrical distribution feeder using hybrid method[J].Energy,2016,103:356-368.
    [20] Deng X,Yuana R,Xiaob Z,et al.Fault location in loop distribution network using SVM technology[J].Electrical Power Energy Systems,2015,65:254-261.
    [21] Wedepohl L M,Nguyen H V,Irwin G D.Frequencydependent transformation matrices for untransposed transmission lines using NewtonRaphson method[J].IEEE Transactions on Power Systems,1996,11(3):1538-1546.
    [22] 邱关源.电路[M].北京:高等教育出版社,2006:279-300.
    [23] LI Mingzhen,ZHOU Chengke,ZHOU Wenjun,et al.A novel fault location method for a crossbonded HV cable system based on sheath current monitoring[J].Sensors,2018,18(10):33-56.
    Related
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

柴鹏,周灏,张煜,史筱川,李爽,杨潇,周苗.基于护层电流时域反演信号的高压电缆短路故障定位方法[J].电力科学与技术学报英文版,2021,36(6):189-195. CHAI Peng, ZHOU Hao, ZHANG Yu, SHI Xiaochuan, LI Shuang, YANG Xiao, ZHOU Miao. Fault location method for highvoltage cable shortcircuit based on electromagnetic time reversal[J]. Journal of Electric Power Science and Technology,2021,36(6):189-195.

Copy
Share
Article Metrics
  • Abstract:255
  • PDF: 964
  • HTML: 0
  • Cited by: 0
History
  • Online: January 05,2022
Article QR Code