Ultra‑low frequency oscillation control method considering dead zone and limiting optimization of hydraulic turbine governor
Author:
Affiliation:

(1. Economic Research Institute, State Grid Hunan Electric Power Co., Ltd., Changsha 410007, China; 2. State Grid Hunan Electric Power Co.,Ltd., Changsha 410004, China; 3. Hunan Provincial Key Laboratory, Energy Internet Supply and Demand Operation, Changsha 410007,China; 4. State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source, North China ElectricPower University, Beijing 102206, China)

Clc Number:

TM712

  • Article
  • | |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • | |
  • Comments
    Abstract:

    The dead zone and limiting of a hydraulic turbine governor have a great influence on the characteristics of the ultra-low frequency oscillations (ULFOs), which can even lead to the oscillation of the positive damping system under large disturbance. However, the existing control methods for ULFOs mainly focus on optimizing proportional?integral?derivative (PID) control parameters of hydraulic turbine governors to improve system damping, without considering the dead zone and limiting parameters concurrently. This paper proposes a ULFO control method considering the dead zone and limiting optimization of the turbine governor and verifies its effectiveness and superiority. Firstly, in a non-smooth single hydro-generator power system (SHPS) with dead zone and limiting, the causes of continuous oscillation with constant amplitude involving dead zone and limiting are analyzed, and the influence of relevant parameters is analyzed, obtaining the qualitative demand for control parameter optimization. Then, a comprehensive evaluation index including the suppression effect of the non-smooth part, the amplification effect of the smooth part, and the performance of the primary frequency regulation is established. Additionally, the optimization parameters are solved using a particle swarm optimization algorithm, and a specific application case of the proposed method is presented. Finally, the proposed method is compared with the control method that does not consider dead zone and limiting optimization, in three simulation systems: SHPS, a four-machine two-area system, and a large-scale power grid model. The proposed method shows improved performance in primary frequency regulation and resistance to disturbance.

    Reference
    Related
    Cited by
Get Citation

王嘉伟,章 德,谢宇峥,薛安成.考虑水轮机调速死区和限幅优化的超低频频率振荡控制方法[J].电力科学与技术学报英文版,2025,40(2):68-79. WANG Jiawei, ZHANG De, XIE Yuzheng, XUE Ancheng. Ultra‑low frequency oscillation control method considering dead zone and limiting optimization of hydraulic turbine governor[J]. Journal of Electric Power Science and Technology,2025,40(2):68-79.

Copy
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Online: June 06,2025
Article QR Code