    摘要:

    系统电容电流的精确测量是谐振接地系统中消弧线圈正确调谐的前提和关键。通过分析现有配电网电容电流测量方法中存在的问题,提出一种测量电容电流的新方法。该方法通过改变消弧线圈电感值的大小,测量电感值改变前后,系统中性点位移电压和中性点电流的幅值和相位,并根据公式计算系统对地总电容及对地总电导,进而计算出系统对地额定电容电流值。最后通过MATLAB仿真验证该方法能够取得较高的测量精度。该方法操作方便,计算简单,可用于消弧线圈的调谐计算。

    Abstract:

    The accurate measurement of system capacitance current is the precondition and key factor for the correct tuning of the arc suppression coil in the resonance grounding system. On the basis of analyzing the existing problems in the capacitor current measurement method of distribution network, a new method for capacitor current measurement is proposed. By changing the inductance value of the arc suppression coil, the amplitude and phase of the neutral point displacement voltage and neutral point current of the system are measured before and after changing the inductance value. According to the formula, the total capacitance and conductance of the system are calculated. And then the rated capacitor current of the system is calculated. Finally, the MATLAB simulation proves that the method can achieve high measurement accuracy. The method is easy to operate and simple to calculate, and it can be used for the tuning calculation of arc suppression coil.

    参考文献
    [1] 要焕年,曹梅月.电力系统谐振接地(第二版)[M].北京:中国电力出版社,2009.
    [2] 李景禄.实用配电网技术[M].北京:中国水利水电出版社,2006.
    [3] 陈忠仁,陈芳靖,李微波.自动消弧线圈的测量及调谐改进方法[J].高压电器,2009,45(2):7780.CHENG Zhongren,CHEN Fangjing,LI Weibo.Improvement method of measuring and tuning of automatic arcsuppression coil[J].High Voltage Apparatus,2009,45(2):7780.
    [4] 李景禄,周羽生,唐跃进.偏置电容法电容电流测量的应用经验[J].电力自动化设备,2004,24(2):99100.LI Jinglu,ZHOU Yusheng,TANG Yuejin.Application experiences of capacitive current measuring with partially installing capacitor[J].Electric Power Automation Equipment,2004,24(2):99100.
    [5] 贺良华,葛来,孙宝金.基于谐振频率预测模型的配电网电容电流测量方法[J].电力系统自动化,2018,42(2):149153.HE Lianghua,GE Lai,SUN Baojin.Capacitive current measuring method for distribution networks based on resonant frequency prediction model[J].Automation of Electric Power Systems,2018,42(2):149153.
    [6] 周求宽,张旭俊,张科杰,等.电力行业标准异频法公式勘误与电容电流测试新方法[J].电力系统自动化,2017,41(1):167173.ZHOU Qiukuan,ZHANG Xujun,ZHANG Kejie,et al.Formula erratum for nonpower frequency method in power industry standard and new measuring method of capacitive current[J].Automation of Electric Power Systems,2017,41(1):167173.
    [7] 吴斌,陈纲,金云奎,等.一种新型的消弧线圈自动跟踪补偿装置[J].电力系统保护与控制,2018,46(19):157163.WU Bin,CHEN Gang,JIN Yunkui,et al.A new type of arcsuppression coil automatic tracking compensation device[J].Power System Protection and Control,2018,46(19):157163.
    [8] 滕昊.带阻尼电阻的谐振接地系统电容电流精确测量方法[J].电力科学与技术学报,2017,32(1):97102.TENG Hao.Accurate measurement method of capacitive current in resonant grounding system with damping resistance[J].Journal of Electric Power Science and Technology,2017,32(1):97102.
    [9] 刘宝稳,李晓波.跟踪补偿消弧装置变参调谐通用方法[J].电力系统及其自动化学报,2015,27(9):16.LIU Baowen,LI Xiaobo.General automatic tuning method of change parameters arcsuppression coil compensation device[J].Proceeding of the CSUEPSA,2015,27(9):16.
    [10] 朱珂,殷鹏,刘颖英,等.利用电力电子扰动技术的系统对地电容检测方法[J].电力系统自动化,2016,40(23):150156.ZHU Ke,YIN Peng,LIU Yingying,et al.Detection method for system grounding capacitance using power electric disturbance technology[J].Automation of Electric Power Systems.2016,40(23):150156.
    [11] 闫腾飞,李康,李晓波,等.基于牛顿拉夫逊法的配电网电容电流测量新方法[J].电力系统保护与控制,2017,45(7):1317.YAN Tengfei,LI Kang,LI Xiaobo,et al.A new capacitive current measurement method of distribution network based on NewtonRaphson method[J].Power System Protection and Control,2017,45(7):1317.
    [12] 方涛,陈豪威,王媛媛,等.基于主频分量相关性的谐振接地配电网故障定位方法[J].电力科学与技术学报,2018,33(1):9094.FANG Tao,CHEN Haowei,WANG Yuanyuan,et al.A novel fault location method based on the waveform correlation of main frequency component for resonant grounding distribution system[J].Journal of Electric Power Science and Technology,2018,33(1):9094.
    [13] 黄宇浩,陈豪威,周佳铭,等.基于暂态零序电流频谱灰关联分析的谐振接地系统故障选线方法[J].电力科学与技术学报,2017,32(3):7176.HUANG Yuhao,CHEN Haowei,ZHOU Jiaming,et al.Faulty feeder detection using grey relation analysis of transient zerosequence current spectrum in resonant grounding system[J].Journal of Electric Power Science and Technology,2017,32(3):7176.
    [14] 李明贤,解洪光,张喜玲,等.基于谐波分量的配电网分相对地参数辨识新方法[J].智慧电力,2019,47(4):99104.LI Mingxian,XIE Hongguang,ZHANG Xiling,et al.A new method for relative parameter identification of distribution network based on harmonic component[J].Smart Power,2019,47(4):99104.
    相似文献
    引证文献
    网友评论
    网友评论
    分享到微博
    发 布
引用本文

张 姗,梁志瑞,张丽芳,等.一种谐振接地系统电容电流测量新方法[J].电力科学与技术学报,2020,35(1):109-114.
ZHANG Shan, LIANG Zhirui, ZHANG Lifang, et al. A new capacitor current measurement method for resonance grounding system[J]. Journal of Electric Power Science and Technology,2020,35(1):109-114.

复制
分享
文章指标
  • 点击次数:195
  • 下载次数: 784
  • HTML阅读次数: 0
  • 引用次数: 0
历史
  • 在线发布日期: 2020-08-20
文章二维码