不对称电网馈线零序电流分布特征分析
CSTR:
作者:
通讯作者:

邓杰文(1988),男,硕士,高级工程师,主要从事变电二次检修工作;Email:timmy1012@qq.com

中图分类号:

TM743


Analysis on distribution characteristics of zero sequence current of feeders in asymmetric grid
Author:
  • 摘要
  • | |
  • 访问统计
  • |
  • 参考文献 [15]
  • | | | |
  • 文章评论
    摘要:

    小电流接地系统在正常运行时,由于线路参数不平衡的普遍存在,系统中性点将产生不平衡电压。不平衡电压在系统馈线中将产生不平衡电流,对该电流的分布特征进行研究,有助于系统故障分析。该文从理论上分析不平衡电流在系统馈线中的分布特征,从馈线的视角出发,通过戴维南定理对系统电路进行等效,得到各馈线不平衡电流表达式。以此为基础求得单相接地故障时馈线稳态零序全电流表达式,揭示其对单相接地故障下馈线零序电流幅值与相位的影响。提出通过对故障前后馈线零序电流作差消除不平衡电流的影响。最后,在matlab软件平台搭建仿真模型,验证该文的分析结果。

    Abstract:

    During the operation of small current grounding system, unbalanced voltages would be induced in neutral points as the unbalanced parameters of transmission lines. And this unbalanced voltage produces an unbalanced current in feeder system. Therefore, studying the distribution characteristics of the unbalanced current is helpful for analyzing system faults. This article theoretically analyzed the unbalanced current in feeder systems. Starting from the feeder, the equivalent circuit of the system is obtained based on Thevenin's theorem while the expressions for unbalanced currents in feeders are also obtained. Then, under the condition of the singlephase disconnection fault, the influence of unbalanced currents on the amplitude and phase of zero sequence current on feeder lines is revealed. Finally, the simulation model is built in MATLAB to verify the analytical results.

    参考文献
    [1] 余文辉,李健,陈祖勋.配电网接地故障电压消弧新方法[J].电力科学与技术学报,2012,27(1):6469.YU Wenhui,LI Jian,CHEN Zuxun.A novel voltage arcsuppression method for grounding fault in distribution network[J].Journal of Electric Power Science and Technology,2012,27(1):6469.
    [2] 曾祥君,王媛媛,李健,等.基于配电网柔性接地控制的故障消弧与馈线保护新原理[J].中国电机工程学报,2012,32(16):137143.ZENG Xiangjun,WANG Yuanyuan,LI Jian,et al.Novel principle of faults arc extinguishing & feeder protection based on flexible grounding control for distribution networks[J].Proceedings of the CSEE,2012,32(16):137143.
    [3] 姜博,董新洲,施慎行.基于单相电流行波的配电线路单相接地故障选线方法[J].中国电机工程学报,2014,34(34):62166227.JIANG Bo,DONG Xinzhou,SHI Shenxing.A method of single phase to ground fault feeder selection based on single phase current traveling wave for distribution lines[J].Proceedings of the CSEE,2014,34(34):62166227.
    [4] 但扬清,赵伟,朱艳伟,等.基于ABCDNN的小电流接地故障选线方法[J].智慧电力,2019,47(4):4652.DAN Yangqing,ZHAO Wei,ZHU Yanwei,et al.Fault line selection in small current ground power system based on ABCDNN[J].Smart Power,2019,47(4):4652.
    [5] 赵海龙,陈钦柱,梁亚峰,等.一种小电流接地系统故障行波精确定位方法[J].电力系统保护与控制,2019,47(19):8593.HAO Hailong,CHEN Qinzhu,LIANG Yafeng,et al.A fault location method of single phase earth fault in small current neutral grounding system[J].Power System Protection and Control,2019,47(19):8593.
    [6] 陈柏超,王朋,沈伟伟,等.电磁混合式消弧线圈的全补偿故障消弧原理及其柔性控制策略[J].电工技术学报,2015,30(10):311318.CHEN Baichao,WANG Peng,SHEN Weiwei,et al.The principle of full compensation arc suppression of flexible control of electromagenetic hybrid petersen coil[J].Transactions of China Electrotechnical Society,2015,30(10):311318.
    [7] 郭谋发,陈静洁,张伟骏,等.基于单相级联H桥变流器的配电网故障消弧与选线新方法[J].电网技术,2015,39(9):26772684.GUO Moufa,CHEN Jingjie,ZHANG Weijun,et al.A novel approach for fault arc extinguishing and feeder selection in distribution networks based on singlephase cascade Hbridge converter[J].Power System Technology,2015,39(9):26772684.
    [8] 赵军,袁雪琼,阮琦,等.基于对地参数跟踪测量的不接地系统单相接地故障选相研究[J].电力系统保护与控制,2015,43(21):8185.ZHAO Jun,YUAN Xueqiong,RUAN Qi,et al.Research on single phase grounding fault phase selection based on ground parameter tracking and measurement[J].Power System Protection and Control,2015,43(21):8185.
    [9] 黄跃.配电网接地故障辨识与消弧柜投入控制研究[D].长沙:长沙理工大学,2014.
    [10] 李新泉,齐郑,杨以涵.消弧线圈与接地故障转移装置配合使用的消弧方法[J].电力系统自动化,2008,32(19):7175.LI Xinquan,QI Zheng,YANG Yihan.Arcsuppression method for coordinated using of arcextinguish coil with grounded fault transfer device[J].Automation of Electric Power Systems,2008,32(19):7175.
    [11] 吴乐鹏,黄纯,林达斌,等.基于暂态小波能量的小电流接地故障选线新方法[J].电力自动化设备,2013,33(5):7075.WU Lepeng,HUANG Chun,LIN Dabin,et al.Faulty line selection based on transient wavelet energy for nonsolidearthed network[J].Electric Power Automation Equipment,2013,33(5):7075.
    [12] 李如琦,黄欢,张振兴,等.小电流系统单相不完全接地故障分析[J].广西大学学报:自然科学版,2007,32(4):367370.LI Ruqi,HUANG Huan,ZHANG Zhenxing,et al.Analyzing of singlephase and indirectly grounding fault in small current system[J].Journal of Guangxi University:Natural Science Edition,2007,32(04):367370.
    [13] 秦珣,陈丽安.基于改进导纳法的小电流接地系统接地故障选线方法[J].电力科学与技术学报,2016,31(1):96102.QIN Xun,CHEN Li'an.Improved neutral admittance method based grounding faulted feeder detection for power system with small current earthing[J].Journal of Electric Power Science and Technology,2016,31(1):96102.
    [14] 要焕年,曹梅月.电力系统谐振接地(第2版)[M].北京:中国电力出版社,2009.
    [15] 方涛,陈豪威,王媛媛,等.基于主频分量相关性的谐振接地配电网故障定位方法[J].电力科学与技术学报,2018,33(1):8892.FANG Tao,CHENG Haowei,WANG Yuanyuan,et al.A novel fault location method based on the waveform correlation of main frequency component for resonant grounding distribution system[J].Journal of Electric Power Science and Technology,2018,33(1):8892.