基于配电网双端信息融合的单相断线故障实时监测方法
作者:
作者单位:

作者简介:

通讯作者:

曾祥君(1972),男,博士,教授,博士生导师,长江学者,主要从事电力系统保护与控制研究;Email:eexjzeng@qq.com

中图分类号:

TM933

基金项目:

国家自然科学基金重点项目(51737002);国网湖南省电力有限公司科技项目(5216A01700AH)


A real time monitoring method for the singleline break fault based on dualterminal information in the distribution network
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    由于配电网结构复杂、运行方式多变,易发生各类断线故障。单相断线故障的故障特征不明显,常规方法难以有效监测,可靠性低。为解决这一问题,提出一种基于配电网双端信息融合的单相断线故障监测方法,通过实时监测电源侧及负载侧电压、电流信号,提取断线故障特征信息,综合建立断线故障识别判据,实现单相断线故障实时监测,该方法显著提高了单相断线故障的识别精度。PSCAD/EMTDC仿真分析结果表明:该方法不受配电线路参数和系统运行方式的影响,能够有效排除其它故障,可靠准确地识别单相断线故障,监测准确、快速,满足配电网安全运行在线监测实时性要求,具有一定的工程应用价值。

    Abstract:

    Due to the complex structure and changeable operation mode, the distribution network frequently suffers from various types of damage such as a line break fault. It is reliability is relatively low since the feature of singleline break fault is not obvious and the conventional detection method is difficult to monitor effectively. In order to solve this problem, a real time monitoring method for the singleline break fault based on dualterminal information in distribution network is proposed in this paper. Firstly, the singleline break fault feature information is extracted by monitoring the relevant voltage and current signals on the power supply side and load side in real time. A comprehensive criterion is established for the identifying singleline break fault to realize the realtime monitoring of singleline break fault. This method can greatly improve the recognition accuracy of singleline break fault. Finally, the simulation is carried out on PSCAD/EMTDC. It is shown that the proposed method is not affected by the distribution line parameters and operation mode. It can effectively eliminates other faults and reliable and accurately identify the singleline break fault. Moreover, the monitoring process is accurate and fast to meet the realtime monitoring requirements for the safe operation of distribution network. It is valuable for engineering applications.

    参考文献
    相似文献
    引证文献
引用本文

曾祥君,陈 磊,喻 锟,等.基于配电网双端信息融合的单相断线故障实时监测方法[J].电力科学与技术学报,2020,35(3):12-18.
ZENG Xiangjun, CHEN Lei, YU Kun, et al. A real time monitoring method for the singleline break fault based on dualterminal information in the distribution network[J]. Journal of Electric Power Science and Technology,2020,35(3):12-18.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2020-09-14
  • 出版日期:
文章二维码