基于区间灰数动态灰靶的变压器状态评估
CSTR:
作者:
中图分类号:

TM407

基金项目:

国家自然科学基金(51777119); 国网浙江省电力有限公司科技项目(2017HZJTKJ03)


A condition assessment method of transformers based upon the dynamic grey target with the interval grey number
Author:
  • 摘要
  • | |
  • 访问统计
  • |
  • 参考文献 [18]
  • | |
  • 引证文献
  • | |
  • 文章评论
    摘要:

    针对目前变压器状态评估缺乏考虑多阶段信息的动态性、变化趋势的现状,提出一种基于区间灰数动态灰靶的变压器状态评估方法。首先,对效益型和成本型指标数据进行归一化处理;其次,引入区间灰数的方差和均差来衡量区间指标数据的波动性,进而赋予指标最佳权重;然后,综合考虑变压器多维时间阶段信息集结和指标的阶段间动态变化,提出一种基于区间灰数动态灰靶的变压器状态评估方法,求取靶心度作为状态评估的依据;最后,通过算例分析某变电站多台变压器多阶段的运行数据,验证了该状态评估方法的客观性和有效性。

    Abstract:

    Nowadays, the condition assessment of transformer doesn't consider the dynamic characteristics and variational tendency of information in different stages. On this background, a dynamic gray target assessment model based on approaching degrees is proposed in this paper. First of all, the index data of benefittype and costtype are standardized. Secondly, the variance and the mean deviation of the interval grey number are introduced to evaluate the data volatility of the interval index. Then, the best weight can be determined. After that, a dynamic grey target evaluation model of interval grey number is proposed considering the accumulation of transformer phase information and the dynamic variation of index. The approaching degree is regarded as the basis of condition assessment. At last, the multistage operation data of multiple transformers in a substation is analyzed to verify the validity of the proposed method.

    参考文献
    [1] 宋人杰,刘瑞英,王林.灰色定权聚类和变权模式在变压器状态评估中的应用研究[J].电工电能新技术,2017,36(3):7580.SONG Renjie,LIU Ruiying,WANG Lin.Application of grey fixed weight clustering and variable weight modelin transformer condition evaluation[J].Advanced Technology of Electrical Engineering and Energy,2017,36(3):7580.
    [2] 张桦,魏本刚,李可军,等.基于变压器马尔可夫状态评估模型和熵权模糊评价方法的风险评估技术研究[J].电力系统保护与控制,2016,44(5):134140.ZHANG Hua,WEI Bengang,LI Kejun,et al.Research on risk assessment technology based on Markov state evaluation model for power transformer and entropy weighted fuzzy comprehensive evaluation[J].Power System Protection and Control,2016,44(5):134140.
    [3] 孙莹,高贺,李可军,等.基于多时段信息融合的配电变压器运行状态评估模型[J].高电压技术,2016,42(7):20542062.SUN Ying,GAO He,LI Kejun,et al.Condition assessment model of distribution transformer based on multiperiod information fusion[J].High Voltage Engineering,2016,42(7):20542062.
    [4] 徐岩,陈昕.基于合作博弈和云模型的变压器状态评估方法[J].电力自动化设备,2015,35(3):8893.XU Yan,CHEN Xin.Transformer status assessment based on cooperative game and cloud model[J].Electric Power Automation Equipment,2015,35(3):8893.
    [5] 卜宪存,张海英.基于区间数TOPSIS法的电力变压器状态评估[J].高压电器,2016,52(4):205209.BU Xiancun,ZHANG Haiying.Condition assessment of power transformer based on intervals TOPSIS[J].High Voltage Apparatus,2016,52(4):205209.
    [6] 杨国生,戴飞扬,王文焕,等.基于灰度关联法和TOPSIS法的继电保护状态评估综合算法研究与应用[J].中国电力,2019,52(2):94103.YANG Guosheng,DAI Feiyang,WANG Wenhuan,et al.Research and application of comprehensive algorithm of relay protection status assessment based on gray correlation analysis and TOPSIS method[J].Electric Power,2019,52(2):94103.
    [7] LIU Zifa,ZHANG Jiechao,LI Cong.Spatial electricload forecasting based on AHP and TOPSIS method[C]//IEEE 8th International Conference on Advances in Power System Control,Operation and Management,Hong Kong,China,2009.
    [8] 廖瑞金,张镱议,黄飞龙,等.基于可拓分析法的电力变压器本体绝缘状态评估[J].高电压技术,2012,38(3):521526.LIAO Ruijin,ZHANG Yiyi,HUANG Feilong,et al.Power transformer condition assessment strategy using matter element analysis[J].High Voltage Engineering,2012,38(3):521526.
    [9] 王涛云,马宏忠,崔杨柳,等.基于可拓分析和熵值法的GIS状态评估[J].电力系统保护与控制,2016,44(8):115120.WANG Taoyun,MA Hongzhong,CUI Yangliu,et al.Condition evaluation of gas insulated switchgear based on extension analysis and entropy method[J].Power System Protection and Control,2016,44(8):115120.
    [10] 马纪,刘希喆.基于序关系—熵权法的低压配网台区健康状态评估[J].电力系统保护与控制,2017,45(6):8793.MA Ji,LIU Xizhe.Evaluation of health status of lowvoltage distribution network based on order relationentropy weight method[J].Power System Protection and Control,2017,45(6):8793.
    [11] 曾丹乐,杜修明,盛戈皞,等.基于因子分析法与DS证据理论的变压器关键参量提取和状态评估[J].高压电器,2016,52(3):714.ZENG Danle,DU Xiuming,SHENG Gehao,et al.Key parameters extraction and condition evaluation of transformer based on factor analysis and DS evidence theory[J].High Voltage Apparatus,2016,52(3):714.
    [12] 廖瑞金,孟繁津,周年荣,等.基于集对分析和证据理论融合的变压器内绝缘状态评估方法[J].高电压技术,2014,40(2):474481.LIAO Ruijin,MENG Fanjin,ZHOU Nianrong,et al.Assessment strategy for inner insulation condition of power transformer based on setpair analysis and evidential reasoning decisionmaking[J].High Voltage Engineering,2014,40(2):474481.
    [13] 林晓宁,蔡金锭.基于粗糙集理论的变压器油纸绝缘状态评估[J].电力系统保护与控制,2019,47(7):2229.LIN Xiaoning,CAI Jinding.Evaluation of transformer oilpaper insulation based on rough set theory[J].Power System Protection and Control,2019,47(7):2229.
    [14] 王岭,蔡金锭.基于剩余电压时域特征的变压器绝缘状态评估方法[J].电力科学与技术学报,2017,32(1):130137.WANG Ling,CAI Jinding.Assessment stratagy on transformer insulation condition based on residual voltage time domain characteristics[J].Journal of Electric Power Science and Technology,2017,32(1):130137.
    [15] 谢松,蔡金锭,林韩.变压器油纸绝缘状态评估方法[J].电力科学与技术学报,2017,32(1):123129.XIE Song,CAI Jinding,LIN Han.Assessment method for transformer oilpaper insulation condition[J].Journal of Electric Power Science and Technology,2017,32(1):123129.
    [16] 杨杰明,董玉坤,曲朝阳,等.基于区间权重和改进云模型的变压器状态评估[J].电力系统保护与控制,2016,44(23):102109.YANG Jieming,DONG Yukun,QU Chaoyang,et al.Condition assessment for transformer based on interval weight and improved cloud model[J].Power System Protection and Control,2016,44(23):102109.
    [17] 闫书丽.灰靶决策方法及应用研究[D].南京:南京航空航天大学,2014.
    [18] CHEN Guojin,XU Ming,LIU Tingting,et al.Research on condition monitoring and evaluation method of power transformer[C]//IEEE 3rd International Conference on Intelligent System Design and Engineering Applications,Zhangjiajie,China,2013.
    相似文献
    引证文献
    网友评论
    网友评论
    分享到微博
    发 布
引用本文

周敬嵩,俞京锋,杨欢红,等.基于区间灰数动态灰靶的变压器状态评估[J].电力科学与技术学报,2020,35(4):133-140.
ZHOU Jingsong, YU Jingfeng, YANG Huanhong, et al. A condition assessment method of transformers based upon the dynamic grey target with the interval grey number[J]. Journal of Electric Power Science and Technology,2020,35(4):133-140.

复制
分享
文章指标
  • 点击次数:333
  • 下载次数: 2804
  • HTML阅读次数: 0
  • 引用次数: 0
历史
  • 在线发布日期: 2020-09-04
文章二维码