    摘要:

    针对城市轨道交通杂散电流引起的变压器直流偏磁问题,提出一种基于振动信号的城市电网变压器直流偏磁状态辨识方法,排除了短路故障、电网谐波干扰对状态辨识的影响。首先,分别对直流偏磁、短路故障、电网谐波干扰下的变压器振动信号的持续时间及频率特征进行分析,研究发现,相比于其他故障,在直流偏磁下变压器振动将加剧,振动信号频率分量复杂化,出现一系列高次谐波分量,特别是50 Hz奇倍频分量增加明显;然后基于此,利用振动信号除100Hz外的50Hz倍频分量的能量之和,排除短路故障对直流偏磁状态辨识的影响;其次,利用除 100Hz外的50Hz奇倍频分量与除100Hz外的50Hz倍频分量的能量之和的比值,排除电网谐波干扰对直流偏磁状态辨识的影响,以实现城轨杂散电流引起的变压器直流偏磁的状态辨识;最后,对现场实测数据进行分析及处理, 进一步验证该方法的准确性。

    Abstract:

    Aiming at the problem of transformer DC bias caused by the urban rail transit, this paper proposes a DC bias state identification method based on vibration signal for transformers of urban power grid. Firstly, the time of duration and the frequency characteristics of the transformer vibration signal under the conditions of DC bias, short fault and harmonic interference is analyzed. It is found that compared with other faults, the transformer vibration intensifies under DC magnetic bias. The frequency component of vibration signal becomes complex. A series of high-order harmonic components, especially the 50Hz odd double frequency component, increase significantly. Based on these phenomena, the influence of short circuit fault on DC bias state identification is eliminated by using the sum of energy of 50 Hz octave component of vibration signal except 100 Hz. Then, the ratio of the sum of the energy of 50 Hz odd octave components except 100 Hz over the sum of energy of 50 Hz octave components except 100 Hz is used to eliminate the influence of power grid harmonic interference on DC magnetic bias state identification, so as to realize the state identification of transformer DC magnetic bias caused by urban rail stray current. Finally, the on-site measured data is analyzed and processed to further verify the accuracy of proposed method.

    参考文献
    [1] 文习山,郭婷婷,何智强,等.直流偏磁相关问题研究综述[J].高压电器,2016,52(6):1-8.WEN Xishan,GUO Tingting,HE Zhiqiang,et al.Research summary on the impacts of DC magnetic bias on transformer[J].High Voltage Apparatus,2016,52(6):1-8.
    [2] 乔峰,何英发,翁汉琍,等.变压器直流偏磁对无功功率影响的仿真分析[J].电力科学与技术学报,2016,31(4):102-108.QIAO Feng,HE Yingfa,WENG Hanli,et al.Simulation analysis on the effection of transformers DC magnetic biasing to reactive power consumption[J].Journal of Electric Power Science and Technology,2016,31(4):102-108.
    [3] 王格万,潘超,郑迤丹,等.变压器直流扰动下励磁谐波与铁心饱和失稳研究[J].电力系统保护与控制,2019,47(9):49-55.WANG Gewan,PAN Chao,ZHENG Yidan,et al.Research on excitation harmonics and core saturation instability of transformer under DC disturbance[J].Power System Protection and Control,2019,47(9):49-55.
    [4] 姜朋亮,赵文彬,卢武,等.基于GIC对电网变压器偏磁特性的研究[J].电测与仪表,2021,58(2):25-33.JIANG Pengliang,ZHAO Wenbin,LU Wu,et al.Research on magnetic bias characteristics of power grid transformer based on GIC[J].Electrical Measurement & Instrumentation,2021,58(2):25-33.
    [5] 刘连光,马成廉.一种考虑接地极选址及受端电网结构的偏磁电流减小方法[J].中国电力,2021,54(7):100-108.LIU Lianguang,MA Chenglian.A DC bias current reducing method considering grounding electrode location and receiving-end grid structure[J].Electric Power,2021,54(7):100-108.
    [6] 师泯夏,吴邦,靳宇晖,等.直流偏磁对变压器影响研究综述[J].高压电器,2018,54(7):20-43.SHI Minxia,WU Bang,JIN Yuhui,et al.Research summary on the impacts of DC magnetic bias on transformer[J].High Voltage Apparatus,2018,54(7):20-43.
    [7] Wang A,Lin S,Hu Z H,et al.Evaluation model of DC current distribution in AC power systems caused by stray current of DC metro systems[J].IEEE Transactions on Power Delivery,2021,36(1):114-123.
    [8] 罗远国,刘君,毛钧毅,等.轨地过渡电阻对电网地铁杂散电流分布影响分析[J].电网与清洁能源,2021,37(4):32-40.LUO Yuanguo,LIU Jun,MAO Junyi,et al.Analysis of the influence of rail-to-Ground resistance on the stray current distribution in a power grid[J].Power System and Clean Energy,2021,37(4):32-40.
    [9] 宋伟,张波,黄军,等.直流输电地中回流对高速铁路系统影响的仿真研究[J].智慧电力,2020,48(11):9-15.SONG Wei,ZHANG Bo,HUANG Jun,et al.Numerical analysis of influence of ground return current in HVDC ground electrode on high speed railway system[J].Smart Power,2020,48(11):9-15.
    [10] 王爱民,林圣,李俊逸,等.城市轨道交通长线路杂散电流仿真模型[J].高电压技术,2020,46(4):1379-1386.WANG Aimin,LIN Sheng,LI Junyi,et al.Stray current simulation model of the long line of DC metro systems[J].High Voltage Engineering,2020,46(4):1379-1386.
    [11] 彭平,周卫华,谢耀恒,等.关于地铁杂散电流引起的变压器直流偏磁的分析与研究[J].变压器,2017,54(11):26-30.PENG Ping,ZHOU Weihua,XIE Yaoheng,et al.Analysis and research on DC bias of transformer caused by metro stray current[J].Transformer,2017,54(11):26-30.
    [12] 彭平,曾祥君,倪砚茹,等.考虑地铁杂散电流影响的变压器直流偏磁电流建模方法[J].电力科学与技术学报,2021,36(1):192-198.PENG Ping,ZENG Xiangjiun,NI Yanru,et al.Modeling for the DC bias current of transformer caused by the metro stray current[J].Journal of Electric Power Science and Technology,2021,36(1):192-198.
    [13] 王玲,马明,徐柏榆,等.基于非线性磁路方程的变压器直流偏磁风险评估[J].变压器,2018,55(10):55-60.WANG Ling,MA Ming,XU Baiyu,et al.Risk assessment of DC bias of transformer based on nonlinear magnetic circuit equation[J].Transformer,2018,55(10):55-60.
    [14] 李金龙,李金忠,张书琦.变压器拓扑修正暂态模型及其在直流偏磁耐受评估中的应用[J].电网技术,2019,43(9):3439-3447.LI Jinlong,LI Jinzhong,ZHANG Shuqi.Topology correct duality-based transformer transient model and its application in DC bias assessment[J].Power System Technology,2019,43(9):3439-3447.
    [15] 谢志成,钱海,林湘宁,等.直流偏磁下变压器运行状态量化评估方法[J].电力自动化设备,2019,39(2):216-223.XIE Zhicheng,QIAN Hai,LIN Xiangning,et al.Quantitative state assessment method for transformer under DC bias[J].Electric Power Automation Equipment,2019,39(2):216-223.
    [16] 郭洁,黄海,唐昕,等.500 kV电力变压器偏磁振动分析[J].电网技术,2012,36(3):70-75.GUO Jie,HUANG Hai,TANG Xin.Analysis on 500 kV power transformer vibration under DC magnetic biasing[J].Power System Technology,2012,36(3):70-75.
    [17] 吴晓文,周年光,胡胜,等.城市轨道交通引起的变压器直流偏磁噪声与振动特性[J].电测与仪表,2017,54(17):117-122.WU Xiaowen,ZHOU Nianguang,HU Sheng,et al.Audible noise and vibration characteristics of DC-bias in power transformers caused by urban mass transit system[J].Electrical Measurement & Instrumentation,2017,54(17):117-122.
    [18] 李英,黃莹,邹宇星,等.大容量变压器负载噪声的试验研究[J].变压器,2015,52(8):53-58.LI Ying,HUANG Ying,ZOU Yuxing,et al.Test and research of load noise in large transformer[J].Transformer,2015,52(8):53-58.
    [19] 高沛,王丰华,苏磊,等.直流偏磁下电力变压器的振动特性[J].电网技术,2014,38(6):1536-1541.GAO Pei,WANG Fenghua,SU Lei,et al.Analysis on vibration characteristics of power transformer under DC bias[J].Power System Technology,2014,38(6):1536-1541.
    [20] 杨文荣,何源,陈玥.过电压下变压器的振动特性研究[J].实验技术与管理,2019,36(12):123-126.YANG Wenrong,HE Yuan,CHEN Yue.Study on vibration characteristics of transformer under overvoltage[J].Experimental Technology and Management,2019,36(12):123-126.
    [21] 赵莉华,丰遥,谢荣斌,等.谐波对变压器振动特性的影响[J].水电能源科学,2017,35(11):198-202.ZHAO Lihua,FENG Yao,XIE Rongbing,et al.Effects of harmonics on vibration characteristic of transformer[J].Water Resources and Power,2017,35(11):198-202.
    [22] 马宏忠,耿志慧,陈楷,等.基于振动的电力变压器绕组变形故障诊断新方法[J].电力系统自动化,2013,37(8):89-95.MA Hongzhong,GENG Zhihui,CHEN Kai,et al.A new fault diagnosis method for power transformer winding deformation based on vibration[J].Automation of Electric Power Systems,2013,37(8):89-95.
    [23] 马海,周力行.基于直流偏磁影响下变压器本体振动与噪声的在线监测[J].电气技术,2012(9):29-33.MA Hai,ZHOU Lixing.On-line monitoring of transformer vibration and noise based on DC magnetic biasing[J].Electrical Engineering,2012(9):29-33.
    [24] 张凡,汲胜昌,祝令瑜,等.短路冲击下变压器振动频响函数研究[J].西安交通大学学报,2017,51(2):97-103.ZHANG Fan,JI Shengchang,ZHU Lingyu,et al.Frequency response function of short circuit vibration for power transformer[J].Journal of Xi'an Jiaotong University,2017,51(2):97-103.
    [25] 汲胜昌,师愉航,张凡,等.电力变压器振动与噪声及其控制措施研究现状与展望[J].高压电器,2019,55(11):1-17.JI Shengchang,SHI Yuhang,ZHANG Fan,et al.Review on vibration and noise of power transformer and its control measures[J].High Voltage Apparatus,2019,55(11):1-17.
    [26] 李谦,张波,蒋愉宽,等.变电站内短路电流暂态过程及其影响因素[J].高电压技术,2014,40(7):1986-1993.LI Qian,ZHANG Bo,JIANG Yukuan,et al.Transient process of short-circuit current in substations and its influential factors[J].High Voltage Engineering,2014,40(7):1986-1993.
    相似文献
    引证文献
    网友评论
    网友评论
    分享到微博
    发 布
引用本文

刘君,牛唯,赵露,等.基于振动信号的城市电网变压器直流偏磁状态辨识方法[J].电力科学与技术学报,2021,36(5):169-178.
Liu Jun, Niu Wei, Zhao Lu, et al. State identification method for transformer of urban power grid under DC bias based on vibration signal[J]. Journal of Electric Power Science and Technology,2021,36(5):169-178.

复制
分享
文章指标
  • 点击次数:174
  • 下载次数: 831
  • HTML阅读次数: 0
  • 引用次数: 0
历史
  • 在线发布日期: 2021-11-16
文章二维码