基于零序电压调控的配电网对地泄漏电阻测量技术
CSTR:
作者:
通讯作者:

白浩(1987-),男,博士,工程师,主要从事配电自动化、主动配电网、人工智能应用研究;E-mail:baihao@csg.cn

中图分类号:

TM76

基金项目:

广西电网有限责任公司科技项目(ZBKJXM20190061)


Measurement technology of grounding leakage resistance of distribution network based on zero sequence voltage regulation
Author:
  • 摘要
  • | |
  • 访问统计
  • |
  • 参考文献 [16]
  • | | | |
  • 文章评论
    摘要:

    由于大多数传统的配电网对地参数测量方法主要针对配电网对地电容的准确测量,而对地泄漏电阻测量并不精确,且无法消除对地参数测量过程中的消谐电阻和电压互感器内阻抗产生的影响,致使测量结果误差较大;同时,传统测量方法不能广泛适用于不同系统接地方式情况,实际应用较为不便。为此,提出一种基于零序电压调控的配电网对地泄漏电阻测量方法,选择配电网外接特制的带有分接抽头的Y/△接线接地变压器上合适的分接抽头接地,获得一个较小的零序电压,并测量出此时的系统零序电流,将所得电压和电流值通过运算得到系统对地泄漏电阻。利用PSCAD/EMTDC仿真软件对提出的对地泄露电阻测量方法进行仿真验证分析,所得测量结果误差小,且适用于不同的系统接线方式,表明了该方法测量精度高,适用性广,且安全经济,使用便捷。

    Abstract:

    Asmost of the traditional measurement methods for the ground parameters of distribution network are mainly focus on the accurate measurement of the grounding capacitance, the grounding leakage resistance measurement is not accurate. The influence of the harmonic elimination resistance and the internal impedance of the voltage transformer is impossible to be eliminated during the measurement of the ground parameters. The issues mentioned above may result in a large error in the grounding leakage resistance measuring result.Furthermore, traditional measurement methods cannot be widely applied to different system grounding methods, and practical application is relatively inconvenient. To this end, this paper proposes a method for measuring the grounding leakage resistance of distribution network based on zero-sequence voltage regulation. In the proposed method, a small zero sequence voltage is obtained byselecting the appropriate shunting tapon a special Y/△-connected grounding transformer with shuntingtaps in the distribution network to ground.The corresponding zero sequence current of the system is measured.The grounding leakage resistance of the system can be calculated through the obtainedvoltage and current values. The PSCAD/EMTDC simulation software is used to verify and analyze the proposed grounding leakage resistance measurement method. The simulation resultsshow thatthe calculation method is applicable to different system connection mode with small measuring error,which indicates that theproposed method has the advance of high measurement accuracy, wide applicability, safety, economy and convenient use.

    参考文献
    [1] 要焕年,曹梅月.电力配电网谐振接地[M].北京:中国电力出版社,2009:34-36.
    [2] 郭丽伟,薛永端,徐丙垠,等.中性点接地方式对供电可靠性的影响分析[J].电网技术,2015,39(8):2340-2345.GUO Liwei,XUE Yongduan,XU Bingyin,et al.Research on effects of neutral grounding modes on power supply reliability in distribution networks[J].Power System Technology,2015,39(8):2340-2345.
    [3] 陈洁羽,左宝峰,谈震,等.配电网单相接地快速处置装置运行情况研究[J].智慧电力,2022,50(2):75-81.CHEN Jieyu,ZUO Baofeng,TAN Zhen,et al.Operation analysis of rapid disposal device for single-phase grounding fault in distribution network[J].Smart Power,2022,50(2):75-81.
    [4] 李晓波,陈义刚,陈文斌,等.基于小波和深度学习的配电网单相接地故障辨识[J].电测与仪表,2021,58(4):115-120.LI Xiaobo,CHEN Yigang,CHEN Wenbin,et al.Identification of single-phase grounding fault in distribution network basedon wavelet and deep learning[J].Electrical Measurement & Instrumentation,2021,58(4):115-120.
    [5] 刘维功,薛永端,徐丙垠,等.可适应线路结构动态变化的有源消弧算法[J].电网技术,2014,38(7):2008-2013.LIU Weigong,XUE Yongduan,XU Bingyin,et al.An active arc-suppression algorithm adaptable to dynamic structure variation of transmission line[J].Power System Technology,2014,38(7):2008-2013.
    [6] 王巍璋,王淳,尹发根.基于可达矩阵和贝叶斯定理的含分布式电源的配电网故障区段定位[J].中国电力,2021,54(7):93-99+124.WANG Weizhang,WANG Chun,YIN Fagen.Reachability matrix and bayes' theorem based fault section location of power distribution network with distributed generation[J].Electric Power,2021,54(7):93-99+124.
    [7] 陈锐,周丰,翁洪杰,等.基于双闭环控制的配电网单相接地故障有源消弧方法[J].电力系统自动化,2017,41(5):128-133.CHEN Rui,ZHOU Feng,WENG Hongjie,et al.Active arc-suppression method based on double closed-loop control under single-phase grounding faults in distribution networks[J].Automation of Electric Power Systems,2017,41(5):128-133.
    [8] 曾祥君,王媛媛,李健,等.基于配电网柔性接地控制的故障消弧与馈线保护新原理[J].中国电机工程学报,2012,32(16):137-143.ZENG Xiangjun,WANG Yuanyuan,LI Jian,et al.Novel principle of faults arc extinguishing and feeder protection based on flexible grounding control for distribution networks[J].Proceedings of the CSEE,2012,32(16):137-143.
    [9] 孔祥平,李鹏,徐凯,等.直流线路故障再启动功能与换流变中性点偏移保护配合策略分析[J].高压电器,2022,58(3):155-162.KONG Xiangping,LI Peng,XU Kai,et al.Coordination strategy analysis between the DC line failure recovery function and neutral shifting protection of converter transformer[J].High Voltage Apparatus,2022,58(3):155-162.
    [10] 李卫丰,王超,薛永端,等.基于暂态功率方向的柔性直流配电网线路单极接地保护方法[J].电力系统保护与控制,2021,49(23):1-10.LI Weifeng,WANG Chao,XUE Yongduan,et al.A flexible DC distribution network line unipolar grounding protection method based on transient power direction[J].Power System Protection and Control,2021,49(23):1-10.
    [11] JIANG Nan,LI Suichao,WANG Lu,et al.A new method of measuring capacitance current in non-effective grounding power system[C]//2016 International Conference on Condition Monitoring and Diagnosis(CMD),Xi'an,China,2016,489-492.
    [12] 李一博.基于柔性全补偿消弧装置的配电网对地电容电流测置技术研究[D].郑州:华北水利水电大学,2019.
    [13] 郑康霖,耿增玮,王红霞,等.基于同步量测大数据的配网单相接地故障检测及定位方法[J].电网与清洁能源,2020,36(9):50-56.ZHENG Kanglin,GENG Zengwei,WANG hongxia,et al.Single-phase grounding fault detection and localization based on big data from synchronized phasor measurement[J].Power System and Clean Energy,2020,36(9):50-56.
    [14] 曾祥君,卓超,喻锟,等.基于接地变压器绕组分档调压干预的配电网主动降压消弧与保护新方法[J].中国电机工程学报,2020,40(5):1523-1534.ZENG Xiangjun,ZHUO Chao,YU Kun,et al.A novel method of faults arc extinguishing and feeder protection based on voltage regulating intervention with grounding transformer winding taps for distribution networks[J].Proceedings of the CSEE,2020,40(5):1523-1534.
    [15] 卓超,曾祥君,喻锟,等.基于双电压互感器的中性点不接地配电网对地参数实时测量新技术[J].电网技术,2020,44(7):2657-2664.ZHUO Chao,ZENG Xiangjun,YU Kun,et al.A novel real-time measurement technique of grounded parameters of dual voltage transformers in neutral point ungrounded distribution networks[J].Power System Technology,2020,44(7):2657-2664.
    [16] 许正亚.变压器及中低压网络数字式保护[M].北京:中国水利水电出版社,2004:35-38.
    相似文献
    引证文献
    网友评论
    网友评论
    分享到微博
    发 布
引用本文

白浩,欧阳健娜,潘姝慧,等.基于零序电压调控的配电网对地泄漏电阻测量技术[J].电力科学与技术学报,2022,37(3):126-132.
BAI Hao, OUYANG Jianna, PAN Shuhui, et al. Measurement technology of grounding leakage resistance of distribution network based on zero sequence voltage regulation[J]. Journal of Electric Power Science and Technology,2022,37(3):126-132.

复制
分享
文章指标
  • 点击次数:200
  • 下载次数: 971
  • HTML阅读次数: 0
  • 引用次数: 0
历史
  • 在线发布日期: 2022-07-24