一种改进型闭锁重合闸信号跨双网配合方式及其风险分析
CSTR:
作者:
通讯作者:

宋劲扬(1996—),男,助理工程师,主要从事电力保护与监控的研究;E-mail:sjy18819002853@163.com

中图分类号:

TM63

基金项目:

国家自然科学基金(51877012)


An improved cross double network locking reclosing signal coordination mode and its risk analysis
Author:
  • 摘要
  • | |
  • 访问统计
  • |
  • 参考文献 [19]
  • | | | |
  • 文章评论
    摘要:

    目前,智能变电站的110 kV线路大多采用双重化线路保护,并且为每套保护配置过程层双网。由于智能站建设初期规范不一致,部分智能站的双重化保护闭锁重合闸配合方式存在跨双网的问题。针对上述问题,首先,研究110 kV线路双重化保护网络结构,分析双重化保护相互闭锁重合闸配合逻辑,提出一种改进型跨双网闭锁重合闸配合方式,给出变电站闭锁重合闸信号跨网通信风险计算方法;然后,以某220 kV智能变电站110 kV双重化线路为例进行案例分析,结果表明本文方法可以大幅提高通信可靠性;最后,以实际变电站为例对本文所提方法进行风险计算,为提升智能站跨双网通信的可靠性提供指导方法。

    Abstract:

    At present, 110 kV lines of smart substation mostly adopt double line protection, and the process layer double network is configured for each protection. Due to the inconsistent specifications in the early stage planning of smart stations, there is a potential cross-dual network problem in the double protection lock-reclosing coordination mode of some smart stations. In view of this, this paper studies the dual protection network structure of 110 kV transmission lines, and analyzes the coordination logic of mutual lock-reclosing of dual protections. An improved cross double network locking reclosing coordination mode is proposed. The calculation method of cross-network communication risks of substation blocking reclosing signals is given. Then the 110 kV double lines of 220 kV smart substation are taken as an example for case analysis, the results show that the proposed method greatly improves the communication reliability. Finally, the data in an actual substation is taken to calculate the risk of the method, which provides a guideline for improving the reliability of intelligent station cross dual network communication.

    参考文献
    [1] 杨志宏,周斌,张海滨,等.智能变电站自动化系统新方案的探讨[J].电力系统自动化,2016,40(14):1-7.YANG Zhihong,ZHOU Bin,ZHANG Haibin,et al.Discussion on novel scheme of smart substation automation system[J].Automation of Electric Power Systems,2016,40(14):1-7.
    [2] 陈德辉,须雷,赵希才.智能变电站自动化与保护核心IEC标准的进展与分析[J].电力系统自动化,2019,43(21):229-239.CHEN Dehui,XU Lei,ZHAO Xicai.Development and analysis of core IEC standards for smart substation automation and relay protection[J].Automation of Electric Power Systems,2019,43(21):229-239.
    [3] 张晓华,蔡巍,武宇平,等.基于红外检测的变电站设备热状态诊断[J].智慧电力,2021,49(9):109-116.ZHANG Xiaohua,CAI Wei,WU Yuping,et al.Thermal state diagnosis of substation equipment based on infrared detection[J].Smart Power,2021,49(9):109-116.
    [4] 胡迅,彭道刚,张浩,等.基于IEC 61850的智能馈线自动化通信技术研究[J].电力科学与技术学报,2017,32(4):108-114.HU Xun,PENG Daogang,ZHANG Hao,et al.Research on communication technology for smart feeder automation based on IEC 61850[J].Journal of Electric Power Science and Technology,2017,32(4):108-114.
    [5] LIU N,ZHANG J H,WU X.Asset analysis of risk assessment for IEC 61850-based power control systems,part I:methodology[J].IEEE Transactions on Power Delivery,2010,26(2):876-881.
    [6] 朱寰,刘国静,李琥,等.“新基建”下变电站资源综合利用发展研究[J].电网与清洁能源,2021,37(3):54-64.ZHU Huan,LIU Guojing,LI Hu,et al.Research on development of comprehensive utilization of substation resources under "new infrastructure construction"[J].Power System and Clean Energy,2021,37(3):54-64.
    [7] 胡定林.数字化变电站220 kV双重化线路保护重合闸功能相互配合方法探讨[J].科技与创新,2014(10):56-57.HU Dinglin.Digital substation of 220 kV double circuit protection reclosing function method of mutual cooperation[J].Science and Technology & Innovation,2014(10):56-57.
    [8] 熊剑,刘陈鑫,邓烽.智能变电站集中式保护测控装置[J].电力系统自动化,2013,37(12):100-103.XIONG Jian,LIU Chenxin,DENG Feng.Centralized protection and monitoring devices of smart substation[J].Automation of Electric Power Systems,2013,37(12):100-103.
    [9] 宋亮亮,汪萍,袁宇波,等.双重化配置线路保护的重合闸功能运行分析[J].电力工程技术,2014,33(1):18-21.SONG Liangliang,WANG Ping,YUAN Yubo,et al.Analysis on reclosing function operation of double configured line protection devices[J].Electric Power Engineering Technology,2014,33(1):18-21.
    [10] 何金栋,王宇,赵志超,等.智能变电站嵌入式终端的网络攻击类型研究及验证[J].中国电力,2020,53(1):81-91.HE Jindong,WANG Yu,ZHAO Zhichao,et al.Type and verification of network attacks on embedded terminals of intelligent substation[J].Electric Power,2020,53(1):81-91.
    [11] 樊陈,倪益民,窦仁辉,等.智能变电站过程层组网方案分析[J].电力系统自动化,2011,35(18):67-71.FAN Chen,NI Yimin,DOU Renhui,et al.Analysis of network scheme for process layer in smart substation[J].Automation of Electric Power Systems,2011,35(18):67-71.
    [12] 谢志迅,邓素碧,臧德扬.数字化变电站通信网络冗余技术[J].电力自动化设备,2011,31(9):100-103+120.XIE Zhixun,DENG Subi,ZANG Deyang.Redundancy technique of digital substation communication network[J].Electric Power Automation Equipment,2011,31(09):100-103+120.
    [13] 张颖,曾翔,文明,等.数字化变电站通信冗余实施方案的改进及可靠性分析[J].电力系统保护与控制,2012,40(5):124-128.ZHANG Ying,ZENG Xiang,WEN Ming,et al.Improvement of redundant communication in digital substation and its reliability analysis[J].Power System Protection and Control,2012,40(5):124-128.
    [14] 戴志辉,方伟,邱小强,等.基于GOOSE反馈机制的智能变电站过程层网络备用方法[J/OL].电测与仪表:1-9[2022-01-25].https://kns.cnki.net/kcms/detail/23.1202.TH.20220124.1520.006.html.DAI Zhihui,FANG Wei,QIU Xiaoqiang,et al.A backup approach for process-level network of smart substation based on GOOSE feedback mechanism[J/OL].Electrical Measurement & Instrumentation,1-9[2022-01-25].https://kns.cnki.net/kcms/detail/23.1202.TH.20220124.1520.006.html.
    [15] 王松,裘愉涛,侯伟宏,等.智能变电站继电保护GOOSE网络跳闸探讨[J].电力系统自动化,2015,39(18):140-144.WANG Song,QIU Yutao,HOU Weihong,et al.Discussion of GOOSE network trip mode for smart substation[J].Automation of Electric Power Systems,2015,39(18):140-144.
    [16] 杜双育,王先培,谢光彬,等.基于IEC 61850的变电站自动化系统可靠性评估[J].电力系统保护与控制,2012,45(5):32-36.DU Shuangyu,WANG Xianpei1,XIE Guangbin,et al.Reliability evaluation of substation automation system based on IEC 61850[J].Power System Protection and Control,2012,45(5):32-36.
    [17] 张璞,张波,王建,等.计及主设备时变状态的变电站短时风险评估方法[J].电力系统保护与控制,2021,49(14):73-81.ZHANG Pu,ZHANG Bo,WANG Jian,et al.Short-term risk assessment for a power substation considering the time-varying operation conditions of power equipment[J].Power System Protection and Control,2021,49(14):73-81.
    [18] PANTELI M,KIRSCHEN D S.Assessing the effect of failures in the information and communication infrastructure on power system reliability[C]//IEEE/PES Power Systems Conference and Exposition(PSCE),Phoenix,Arizona,USA,2011.
    [19] 张小建,吴军民.智能变电站网络交换机信息模型及映射实现[J].电力系统保护与控制,2013,41(10):134-139.ZHANG Xiaojian,WU Junmin.Information model and mapping implementation of Ethernet switches in smart substation[J].Power System Protection and Control,2013,41(10):134-139.
    相似文献
    引证文献
    网友评论
    网友评论
    分享到微博
    发 布
引用本文

宋劲扬,黄潇恺,李舒适,等.一种改进型闭锁重合闸信号跨双网配合方式及其风险分析[J].电力科学与技术学报,2022,37(6):173-180.
SONG Jinyang, HUANG Xiaokai, LI Shushi, et al. An improved cross double network locking reclosing signal coordination mode and its risk analysis[J]. Journal of Electric Power Science and Technology,2022,37(6):173-180.

复制
分享
文章指标
  • 点击次数:226
  • 下载次数: 983
  • HTML阅读次数: 0
  • 引用次数: 0
历史
  • 在线发布日期: 2023-01-16
文章二维码