考虑平抑直流故障后功率波动的储能系统选址配置方法
作者:
作者单位:

(1.国网江苏省电力有限公司电力科学研究院,江苏 南京 210024;2.长沙理工大学电气与信息工程学院,湖南 长沙 410114)

作者简介:

通讯作者:

李泽文(1975—),男,博士,教授,博士生导师,主要从事电力系统保护与控制、电力设备能效优化研究;E?mail:lzw0917@163.com

中图分类号:

TM743

基金项目:

国家电网有限公司总部科技项目(5419?201918206A?0?0?00)


Site selection and configuration method of energy storage system for suppressing power fluctuation after DC fault
Author:
Affiliation:

(1.Electric Power Research Institute, State Grid Jiangsu Electric Power Co., Ltd., Nanjing 210024,China;2. School of Electrical & Information Engineering, Changsha University of Science & Technology, Changsha 410114,China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    多馈入直流系统在受端交流故障发生后,易导致多条直流同时换相失败造成系统功率的大量短缺,产生有功功率波动。为实现对多馈入直流输电系统受端交流故障后电网功率波动的有效抑制,从交直流交互作用强度及有功功率关键节点、线路的角度出发,提出一种平抑换相失败后交流系统有功功率波动的储能系统选址布点方法。首先依据多馈入交互作用因子确定候选区域,然后由多馈入有效短路比确定候选站点,最后以全网有功功率波动率确定储能系统具体选址位置。基于修改的IEEE?39节点系统,在PSCAD中搭建仿真模型,通过仿真验证,提出的储能系统选址方法能够有效减少受端交流故障导致直流换相失败带来的功率波动,提高交流系统的稳定性。

    Abstract:

    After the receiving?end AC fault occurs in the multi?infeed HVDC system, it is easy to cause simultaneous commutation failure of multiple DCs, resulting in a large quantity of power shortage and active power fluctuation. In order to achieve effective suppression of grid power fluctuation after the receiving?end AC faults in the multi?infeed HVDC transmission system, from the perspective of AC/DC interaction strength and the critical nodes and lines of active power, a siting method of the energy storage system is proposed for suppressing power fluctuation of the AC system after commutation failure is proposed. Firstly, the candidate areas are determined according to the multi?infeed interaction factor(MIIF), and then the candidate sites are determined by the multi?infeed effective short circuit ratio(MIESCR). Finally, the specific location of the energy storage system is determined by the active power fluctuation rate of the whole network(APFRWN). The simulation results are verified in PSCAD based on the modified IEEE?39 bus system. The location method of the energy storage system proposed in this paper can effectively reduce the power fluctuation caused by DC commutation failure caused by AC fault at the receiving end and improve the stability of the AC system.

    参考文献
    相似文献
    引证文献
引用本文

吴盛军,李 强,彭维馨,等.考虑平抑直流故障后功率波动的储能系统选址配置方法[J].电力科学与技术学报,2023,38(1):35-42.
WU Shengjun, LI Qiang, PENG Weixin, et al. Site selection and configuration method of energy storage system for suppressing power fluctuation after DC fault[J]. Journal of Electric Power Science and Technology,2023,38(1):35-42.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-04-10
  • 出版日期:
文章二维码