(1.College of Electrical and Information Engineering, Hunan University, Changsha 410082, China; 2.Electric Power Research Institute, State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China; 3. Electric Power Research Institute, State Grid Hunan Electric Power Co., Ltd., Changsha 410017, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    针对户用光伏的大量无序接入导致低压配电网附加损耗严重增大的问题,对配电网附加损耗的量化分析是实现电力系统节能降损的必要途径之一。以户用光伏接入电网后的附加损耗为对象,研究考虑户用光伏发电与配电线路附加损耗的量化关系。首先,对户用光伏接入下附加损耗的变化表征进行理论分析,建立有源低压配电网三相四线制等效电路与数学模型;然后,研究户用光伏不同容量与接入相序下的多类型电能质量扰动情况,建立复合电能质量扰动附加损耗模型;最后,依据典型日的光伏出力功率曲线与附加损耗模型,通过算例分析并验证了所提长时间尺度下户用光伏对配电网附加损耗的量化评估方法的准确性。

    Abstract:

    Quantitative analysis of additional losses in low-voltage distribution networks is one of the necessary ways to achieve energy conservation and loss reduction in power systems, in response to the serious increase in additional losses caused by the disorderly access of household photovoltaics. This paper focuses on the quantitative relationship between the additional losses of household photovoltaic power generation and distribution lines after being connected to the power grid. Firstly, a theoretical analysis is conducted on the changes in characterization of additional losses for household photovoltaic (PV) access. An equivalent circuit and mathematical model are established for active low-voltage distribution networks with three-phase four-wire systems. Secondly, the study investigates the disturbance of multiple types of power quality under different capacities and phase sequences of household PV and establishes a composite power quality disturbance additional loss model. Finally, based on the typical daily PV power output curve and additional loss model, the accuracy of the proposed quantification evaluation method for household PV's additional losses in distribution networks is analyzed and verified through case studies.

    参考文献
    相似文献
    引证文献
引用本文

韩 宇,周 前,李 勇,等.户用光伏接入的低压配电网电能质量问题分析与附加损耗量化评估[J].电力科学与技术学报,2024,(3):177-186.
HAN Yu, ZHOU Qian, LI YONG, et al. Analysis of power quality issues and quantitative evaluation of additional losses in low voltage distribution networks connected to household photovoltaics[J]. Journal of Electric Power Science and Technology,2024,(3):177-186.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2024-07-25
  • 出版日期:
文章二维码