计及LVRT的光伏并网系统暂态稳定性分析与参数优化研究
CSTR:
作者:
作者单位:

(1.国网江西省电力有限公司电力科学研究院,江西 南昌 330096;2.西南交通大学电气工程学院,四川 成都 610031;3.国网江西省电力有限公司,江西 南昌 330096)

作者简介:

通讯作者:

张权旺(2001—),男,硕士研究生,主要从事新能源电力系统暂态稳定性分析等方面的研究;E?mail:zhangquanwang_wt@163.com

中图分类号:

TM712

基金项目:

国网江西省电力有限公司科技项目(521820220006)


Transient stability analysis and parameter optimization of PV grid‑connected systems considering LVRT
Author:
Affiliation:

(1.Electric Power Research Institute,State Grid Jiangxi Electric Power Co., Ltd., Nanchang 330096, China; 2.School of Electrical Engineering,Southwest Jiaotong University,Chengdu 610031,China; 3.State Grid Jiangxi Electric Power Co., Ltd., Nanchang 330096, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    光伏并网系统在低电压穿越(low voltage ride?through, LVRT)期间若控制参数设置不当易造成自身脱网,尤其是在大规模光伏并网加剧电力系统电力电子化程度的情况下,会显著降低系统暂态稳定性水平。为提升系统暂态稳定性,首先,基于光伏并网系统电压跌落期间的运行方式,采用矢量图分析故障持续期间的系统暂态稳定特征;然后,采用单目标线性规划求解方法刻画有功电流指令在暂态稳定约束下的绝对稳定区间,并基于该区间采用几何分析法确定光伏并网系统控制参数的最优区间;最后,对江西某区域实际电网结构进行仿真分析,验证所提参数优化方法对系统暂态稳定性的提升效果。

    Abstract:

    Improper setting of control parameters during low voltage ride-through (LVRT) in photovoltaic (PV) grid-connected systems can easily cause their own disconnection, especially when large-scale PV grid connection exacerbates the degree of power electronics in the power system, which can significantly reduce the transient stability of the system. To improve the transient stability of the system, firstly, based on the operating mode of the PV grid-connected system during voltage drop, vector plots are used to analyze the transient stability characteristics of the system during the duration of the fault. Secondly, the single objective linear programming method is used to describe the absolute stability interval of active current command under transient stability constraints, and based on this interval, the geometric analysis method is used to determine the optimal interval of control parameters of the PV grid-connected system. Finally, simulation analysis is conducted on the actual power grid structure of a certain region in Jiangxi Province to verify the effectiveness of the proposed parameter optimization method in improving the transient stability of the system.

    参考文献
    相似文献
    引证文献
引用本文

陈 波,张权旺,刘 柳,等.计及LVRT的光伏并网系统暂态稳定性分析与参数优化研究[J].电力科学与技术学报,2024,39(6):162-173.
CHEN Bo, ZHANG Quanwang, LIU Liu, et al. Transient stability analysis and parameter optimization of PV grid‑connected systems considering LVRT[J]. Journal of Electric Power Science and Technology,2024,39(6):162-173.

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2025-02-14
  • 出版日期: